Q-See QD54231Z Manuel de service

Naviguer en ligne ou télécharger Manuel de service pour Caméras de sécurité Q-See QD54231Z. Q-See QD54231Z Technical Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Integrated Intelligent Speed Dome
Users Manual
Version 1.0
Vue de la page 0
1 2 3 4 5 6 ... 35 36

Résumé du contenu

Page 1

Integrated Intelligent Speed Dome User’s Manual Version 1.0

Page 2 - Table of Contents

6 1.3.2 Performance Specifications Built-in Decode All digital design. All data are in the connection board. No data loss when power off occur

Page 3

7 2 Address, Baud Rate and Parity setup Before you operate, you need to set address, baud rate and parity. Otherwise you can not control the product

Page 4

8 Figure 2-1 2.2 Set address dial switch Figure 2-2 The encode mode adopts binary system. 1 to 8 is valid bit. The highest address bit is 255.

Page 5

9 7 ON ON ON OFF OFF OFF OFF OFF 8 OFF OFF OFF ON OFF OFF OFF OFF …… ………………………………………………………………… 254 OFF ON ON ON ON ON ON ON 255 ON ON ON ON ON ON ON

Page 6

10 3 Cable Connection 3.1 Multiple-function Composite Cable The multiple-function composite cable includes the video connection port, RS485 conne

Page 7 - 1 Features and Functions

11 Figure 3-2 Note: Please use shielded twisted pair. The shielded layer shall connect to GND firmly; otherwise it may affect communication or vide

Page 8

12 Please contact us freely if some matrix systems do not support dome camera communication protocol. The most direct and easy way is to use current

Page 9 - 1.3 Specifications

13 ADDR :001-H BAUD RATE :9600 PARITY :NONE SOFTWARE :V1.00.0.R 4 Menu 4.1 Screen Menu Index Note: ERR me

Page 10

14 SYSTEM INFORMATION DISPLAY SETTING CAMERA SETTING FUNCTION SETTING EXIT After installation, please connect speed dome to power. The system goes

Page 11

15 ADDR :001-H BAUD RATE :9600 PARITY :NONE SOFTWARE :V1.00.0.R BACK EXIT 4.2.1 System Information  INITIAL INFORMATION: Move t

Page 12

ii Table of Contents 1 FEATURES AND FUNCTIONS ... 3 1.1 General

Page 13

16  ADDR-SOFT: You can set address via software. It is to say, you can use menu to modify dome address. The value ranges from 1 to 254  BACK: Go

Page 14 - 3 Cable Connection

17  WB MODE: Set white balance mode: auto/ATW/outdoor/indoor/outdoor auto/NA lamp auto/ NA lamp. Please use the left/right button on the keyboard o

Page 15

18 o Manual: It becomes valid after you set the gain setting, shutter, iris setting, wide dynamic region (WDR). o IRIS PRIO: It becomes valid afte

Page 16 - Figure 3-5

19 DAY/NIGHT : AUTO (AUTO /NIGHT/DAY) THRESHOLD: :5 (1~8) SAVE BACK EXIT PICTURE FLIP :OFF (ON/OFF) FREEZE FUNC :OFF (ON/OFF) AF

Page 17 - 4 Menu

20 PRESET AUTO PAN AUTO SCAN AUTO CRUISE AUTO PATTERN IDLE MOTION NEXT PAGE BACK EXIT PRESET NO. : 001 TITLE : PRESET 001 SETTING

Page 18 - 4.2 Menu Operation

21 SCAN NO. : 001 SET LEFT LIMIT SET RIGHT LIMIT SCAN SPEED: 161 RUN STOP BACK EXIT presets. Once you want to modify a preset, you can input the p

Page 19

22  SET RIGHT LIMIT: Here is to set camera right address. Click confirm button to save current setup.  SCAN SPEED: The value ranges from 1 to 255

Page 20 - (ON/OFF)

23 IDLE FUNC : OFF IDLE TIME : 001MIN IDLE ACTION : PRESET PRESET NO :001 AUTO SCAN NO :001 CRUISE NO :001

Page 21 - IRIS PRIO

24 When there is no available command for specified time, dome automatically goes on the previous set functions.  IDLE FUNCTION :There are two m

Page 22

25 a. when this item is not ―off‖ and the menu is open, it will auto exit the menu in a certain period of time if there is no operations to the menu.

Page 23

iii 3 CABLE CONNECTION ... 10 3.1 Multiple-function Com

Page 24

26 5 FAQ 5.1 Daily Maintenance Please clean dome cover regularly to get vivid image. Handle the cover with care. Use water to wash. Don’t use cl

Page 25

27 6 Appendix Ⅰ Thunder Proof and Surge Protection This series speed dome adopts TVS lighting protection technology. It can effectively prevent dama

Page 26

28 7 Appendix Ⅱ About RS485 Bus 7.1 RS485 Bus Main Feature RS485 is semi duplex communication cable of impedance 120Ω . Its max load amount is 32

Page 27

29 7.4 The Problem in Practical Use There are 120Ω device terminal resistance in power socket. There are two connection ways. The first one is show

Page 28

30 In this situation, we recommend RS485 distributor. This device can turn star type connection into the connection that conforms to RS485 bus indust

Page 29

31 8 Appendix Toxic or Hazardous Materials or Elements Component Name Toxic or Hazardous Materials or Elements Pb Hg Cd Cr VI PBB PBDE Sheet Metal ○

Page 30 - 5 FAQ

32 Note  This manual is for reference only. Slight difference may be found in the user interface.  All the designs and software

Page 31

iv 7.4 The Problem in Practical Use ...

Page 32 - 7.1 RS485 Bus Main Feature

Welcome Thank you for purchasing our product! This user’s manual is designed to be a reference tool for the operation of your system. Here you can f

Page 33

2 Important Safeguards and Warnings 1.Electrical safety  All installation and operation here should conform to your local electrical safety codes.

Page 34 - 7.6 RS485 Bus FAQ

3 1 Features and Functions 1.1 General Introduction This series speed dome product is an integrated high intelligent speed dome. It adopts water dr

Page 35

4 Camera scans back and forth regularly in a horizontal field. Here you need to set left and right limit and scan speed. You can set 5 scanning paths

Page 36

5 1.2.16 Idle Motion When there is no available order, you can use menu to set dome idle status after specified duration. The idle status includes t

Commentaires sur ces manuels

Pas de commentaire