5.13 External Alarm Input and Relay Output
For QSD42908 there are 16 alarm in and 4 relay out ports. In Alarmsmenu, you can setup
each external alarm input.
In main menu, move the Active Frameto Alarmsicon and pressENTERkey to enter
into alarms menu as shown in fig 5.22
5.22 Alarms setup
External alarm input setup:
Step 1: Select one alarm input Use【↑【↓】keys to select one alarm input.
Step 2: Alarm type
This is the sensor type. You can select Normal Openor Normal Closeaccording to the
sensor type.
Step 3: Enter into Alarm in Handlingsub menu
In the Alarmsmenu, there are two options for Alarm Handling”. One is “Ignore”, and
the other is “Handle”. If you select the “Handle” option, you can activate Policy and PTZ
Linkage” buttons on the right side. Move the “Active Frame to the “Policybutton and press
ENTERkey, you will enter into “Alarm in Handling” sub menu as shown in fig 5.23